Siemens SICAM P Modbus Map¶
This Siemens SICAM P Modbus map is supported in Modbus Monitor XPF, allowing engineers to quickly test, monitor, and visualize device data without manual register mapping.
This page shows a preview subset of the full device map available in Modbus Monitor XPF.
For Siemens SICAM P deployments, teams often use this map to surface harmonics, power factor, and status data in industrial automation panels and building management systems.
Use This Device Map in Modbus Monitor XPF¶
Start using this device map in minutes - no manual register mapping required.
- Download Modbus Monitor XPF Free Trial
- Compare Modbus Monitor XPF with Other Tools
- Modbus Tester for Windows
Quick Facts¶
- Manufacturer: Siemens
- Model: SICAM P
- Device Type: Power Meter
- Protocol: Modbus
- Typical Use: power monitoring, energy metering, and facility automation
- Available in: Modbus Monitor XPF
Why This Map Matters¶
Instead of manually decoding registers and building your setup from scratch, Modbus Monitor XPF provides a pre-built device map to help engineers test, monitor, and visualize data faster.
Browse all XPF device maps for the full library, explore Siemens device maps to compare related models, and use Compare Modbus Monitor XPF with Other Tools when evaluating fit across your stack.
Register Preview¶
| Signal | Address | Type | Units | Category |
|---|---|---|---|---|
| PF L1 | 400258 | FLOAT32 | - | Power Factor |
| Status of Binary Outputs and Device | 400128 | BIT | - | Status |
| THDU L1 | 400280 | FLOAT32 | - | Harmonics |
| MLFB:16 | 400000 | STRING | - | General |
| Serial number:10 | 400019 | STRING | - | Identification |
| Status of Binary Inputs | 400129 | BIT | - | Status |
| Status of Overflow at Measuring | 400199 | BIT | - | Status |
| PF L2 | 400260 | FLOAT32 | - | Power Factor |
| PF L3 | 400262 | FLOAT32 | - | Power Factor |
| PF | 400264 | FLOAT32 | - | Power Factor |
| THDU L2 | 400282 | FLOAT32 | - | Harmonics |
| THDU L3 | 400284 | FLOAT32 | - | Harmonics |
Common Data Categories¶
- Harmonics
- Power Factor
- Status
Typical Use Cases¶
- Commissioning new devices with a known-good register baseline
- Troubleshooting Modbus communication and addressing issues
- Building HMI dashboards for operational visibility
- Logging device telemetry for analysis and reporting
Related Device Maps¶
- Siemens PAC4200 Modbus Map
- Siemens PAC2200 Modbus Map
- Siemens SEM3 Series Modbus Map
- All Siemens Device Maps
- All XPF Device Maps
Use This Device Map in Modbus Monitor XPF¶
Start using this device map in minutes - no manual register mapping required.