Skip to content

Siemens SICAM P Modbus Register Map

The Siemens SICAM P is a power meter used for power monitoring, energy metering, and facility automation. This page provides a sample Modbus register map with addresses, data types, and signal categories to help engineers commission, troubleshoot, and monitor the device. For Siemens SICAM P deployments, teams often use this map to surface harmonics, power factor, and status data in industrial automation panels and building management systems.

This page shows a preview subset of the full device map available in Modbus Monitor XPF.

Engineers searching for Siemens SICAM P Modbus map, Siemens SICAM P register map, or Siemens SICAM P Modbus registers can use this page as a compatibility snapshot before importing the full map into Modbus Monitor XPF.

Overview

  • Device: Siemens SICAM P
  • Type: Power Meter
  • Protocol: Modbus RTU / Modbus TCP
  • Use case: power monitoring, energy metering, and facility automation
  • Works with: Modbus Monitor XPF (import directly)

Download Modbus Map

The full Siemens SICAM P Modbus register map is available inside Modbus Monitor XPF as a pre-built device map. Download the free feature-locked version to access and export the complete map.

Register Table (Sample)

Sample registers from the Siemens SICAM P Modbus map. Import the full map in Modbus Monitor XPF to access all registers.

Signal Address Type Units Category
PF L1 400258 FLOAT32 - Power Factor
Status of Binary Outputs and Device 400128 BIT - Status
THDU L1 400280 FLOAT32 - Harmonics
MLFB:16 400000 STRING - General
Serial number:10 400019 STRING - Identification
Status of Binary Inputs 400129 BIT - Status
Status of Overflow at Measuring 400199 BIT - Status
PF L2 400260 FLOAT32 - Power Factor
PF L3 400262 FLOAT32 - Power Factor
PF 400264 FLOAT32 - Power Factor
THDU L2 400282 FLOAT32 - Harmonics
THDU L3 400284 FLOAT32 - Harmonics

How to Use This Map

  1. Download Modbus Monitor XPFGet the free version.
  2. Select the Siemens SICAM P device map — pre-built maps are bundled and ready to load.
  3. Connect to your device — enter the device IP or COM port and start polling registers immediately.
  4. Visualise and log — build dashboards, trend data, and export readings without manual register entry.

Why Use Pre-Built Maps

  • Saves time — no need to manually look up or enter register addresses
  • Reduces errors — pre-validated maps eliminate mis-typed addresses and wrong data types
  • Speeds commissioning — connect and poll within minutes instead of hours
  • Reusable across projects — use the same map across multiple sites and installations

Data Categories Available

  • Harmonics
  • Power Factor
  • Status