Siemens SEM3 Series Modbus Map¶
This Siemens SEM3 Series Modbus map is supported in Modbus Monitor XPF, allowing engineers to quickly test, monitor, and visualize device data without manual register mapping.
This page shows a preview subset of the full device map available in Modbus Monitor XPF.
For Siemens SEM3 Series deployments, teams often use this map to surface current, power, and status data in industrial automation panels and building management systems.
Use This Device Map in Modbus Monitor XPF¶
Start using this device map in minutes - no manual register mapping required.
- Download Modbus Monitor XPF Free Trial
- Compare Modbus Monitor XPF with Other Tools
- Modbus Tester for Windows
Quick Facts¶
- Manufacturer: Siemens
- Model: SEM3 Series
- Device Type: Power Meter
- Protocol: Modbus
- Typical Use: power monitoring, energy metering, and facility automation
- Available in: Modbus Monitor XPF
Why This Map Matters¶
Instead of manually decoding registers and building your setup from scratch, Modbus Monitor XPF provides a pre-built device map to help engineers test, monitor, and visualize data faster.
Browse all XPF device maps for the full library, explore Siemens device maps to compare related models, and use Compare Modbus Monitor XPF with Other Tools when evaluating fit across your stack.
Register Preview¶
| Signal | Address | Type | Units | Category |
|---|---|---|---|---|
| Monitor 1 current phase 1 Amps | 411906 | FLOAT32 | A | Current |
| Monitor 1 power factor phase 1 1 | 411930 | FLOAT32 | PF | Power |
| Monitor 1 alarm flags | 400200 | UINT16 | - | Status |
| Monitor 1 volts phase 1 Volts | 411900 | FLOAT32 | - | General |
| Monitor 2 alarm flags | 400201 | UINT16 | - | Status |
| Monitor 3 alarm flags | 400202 | UINT16 | - | Status |
| Monitor 4 alarm flags | 400203 | UINT16 | - | Status |
| Monitor 5 alarm flags | 400204 | UINT16 | - | Status |
| Monitor 6 alarm flags | 400205 | UINT16 | - | Status |
| Monitor 7 alarm flags | 400206 | UINT16 | - | Status |
| Monitor 8 alarm flags | 400207 | UINT16 | - | Status |
| Monitor 9 alarm flags | 400208 | UINT16 | - | Status |
Common Data Categories¶
- Current
- Power
- Status
Typical Use Cases¶
- Commissioning new devices with a known-good register baseline
- Troubleshooting Modbus communication and addressing issues
- Building HMI dashboards for operational visibility
- Logging device telemetry for analysis and reporting
Related Device Maps¶
- Siemens PAC4200 Modbus Map
- Siemens PAC2200 Modbus Map
- Siemens SICAM P Modbus Map
- All Siemens Device Maps
- All XPF Device Maps
Use This Device Map in Modbus Monitor XPF¶