Siemens PAC3200 Modbus Register Map

The Siemens PAC3200 is a power meter used for power monitoring, energy metering, and facility automation. This page provides a sample Modbus register map with addresses, data types, and signal categories to help engineers commission, troubleshoot, and monitor the device. For Siemens PAC3200 deployments, teams often use this map to surface power, voltage, and current data in industrial automation panels and building management systems.

This page shows a public register preview. Check the catalog in your installed XPF version for complete-map availability and licensing.

Confirm the exact model and firmware, address base, register function, word order, scaling and units against the manufacturer manual before polling. This preview does not establish hardware validation.

Overview

  • Device: Siemens PAC3200
  • Type: Power Meter
  • Protocol: Confirm the supported transport for the exact device and firmware in the manufacturer manual.
  • Use case: power monitoring, energy metering, and facility automation
  • Works with: Modbus Monitor XPF (import directly)

Download Modbus Map

The sample below is a public preview. Check the catalog in your installed XPF version for current availability, access and licensing.

Public JSON preview · Preview data terms

Register Table (Sample)

Sample registers from the Siemens PAC3200 Modbus map. Confirm the sample against the exact device and firmware before use.

Signal Address Type Units Category
Voltage Va n 400001 FLOAT32 V Voltage
Current a 400013 FLOAT32 - Current
Apparent Power a 400019 FLOAT32 kW Power
Energy pulse mode 450041 FLOAT32 kWh Energy
Frequency 400055 FLOAT32 Hz Frequency
Demand Period 400517 FLOAT32 kW Demand
Device Diagnostics and Device Status 400205 FLOAT32 - Status
Limit Violations 400203 FLOAT32 - General
IP address 463001 FLOAT32 - Communication
Bootloader version 463007 FLOAT32 - Identification
Voltage Vb n 400003 FLOAT32 V Voltage
Voltage Vc n 400005 FLOAT32 V Voltage

How to Use This Map

  1. Download Modbus Monitor XPF — Get the free version.
  2. Select the Siemens PAC3200 device map — check availability and access in the installed application catalog.
  3. Connect to your device — confirm transport, addressing and data types before starting a read operation.
  4. Visualise and log — build dashboards, trend data, and export readings without manual register entry.

Why Use Pre-Built Maps

  • Saves time — no need to manually look up or enter register addresses
  • Reduces errors — reusable maps reduce repeated manual entry; validate addresses and data types for your device
  • Speeds commissioning — connect and poll within minutes instead of hours
  • Reusable across projects — use the same map across multiple sites and installations

Data Categories Available

  • Power
  • Voltage
  • Current
  • Status
  • Demand
  • Frequency