Skip to content

Siemens PAC2200 Modbus Register Map

The Siemens PAC2200 is a power meter used for power monitoring, energy metering, and facility automation. This page provides a sample Modbus register map with addresses, data types, and signal categories to help engineers commission, troubleshoot, and monitor the device. For Siemens PAC2200 deployments, teams often use this map to surface power, current, and voltage data in industrial automation panels and building management systems.

This page shows a public register preview. Check the catalog in your installed XPF version for complete-map availability and licensing.

Confirm the exact model and firmware, address base, register function, word order, scaling and units against the manufacturer manual before polling. This preview does not establish hardware validation.

Overview

  • Device: Siemens PAC2200
  • Type: Power Meter
  • Protocol: Confirm the supported transport for the exact device and firmware in the manufacturer manual.
  • Use case: power monitoring, energy metering, and facility automation
  • Works with: Modbus Monitor XPF (import directly)

Download Modbus Map

The sample below is a public preview. Check the catalog in your installed XPF version for current availability, access and licensing.

Public JSON preview · Preview data terms

Register Table (Sample)

Sample registers from the Siemens PAC2200 Modbus map. Confirm the sample against the exact device and firmware before use.

Signal Address Type Units Category
Voltage UL1 N 400002 FLOAT32 V Voltage
Current L1 400014 FLOAT32 A Current
Apparent power L1 400020 FLOAT32 kW Power
Secondary total of active energy im port 400962 DOUBLE64 kWh Energy
Frequency 400056 FLOAT32 Hz Frequency
Device diagnostics and device status 400206 UINT32 - Status
Active tariff 400212 UINT32 - General
Voltage UL2 N 400004 FLOAT32 V Voltage
Voltage UL3 N 400006 FLOAT32 V Voltage
Voltage UL1 L2 400008 FLOAT32 V Voltage
Voltage UL2 L3 400010 FLOAT32 V Voltage
Voltage UL3 L1 400012 FLOAT32 V Voltage

How to Use This Map

  1. Download Modbus Monitor XPF — Get the free version.
  2. Select the Siemens PAC2200 device map — check availability and access in the installed application catalog.
  3. Connect to your device — confirm transport, addressing and data types before starting a read operation.
  4. Visualise and log — build dashboards, trend data, and export readings without manual register entry.

Why Use Pre-Built Maps

  • Saves time — no need to manually look up or enter register addresses
  • Reduces errors — reusable maps reduce repeated manual entry; validate addresses and data types for your device
  • Speeds commissioning — connect and poll within minutes instead of hours
  • Reusable across projects — use the same map across multiple sites and installations

Data Categories Available

  • Power
  • Current
  • Voltage
  • Energy
  • Status
  • Frequency