Siemens PAC2200 Modbus Register Map¶
The Siemens PAC2200 is a power meter used for power monitoring, energy metering, and facility automation. This page provides a sample Modbus register map with addresses, data types, and signal categories to help engineers commission, troubleshoot, and monitor the device. For Siemens PAC2200 deployments, teams often use this map to surface power, current, and voltage data in industrial automation panels and building management systems.
This page shows a preview subset of the full device map available in Modbus Monitor XPF.
Engineers searching for Siemens PAC2200 Modbus map, Siemens PAC2200 register map, or Siemens PAC2200 Modbus registers can use this page as a compatibility snapshot before importing the full map into Modbus Monitor XPF.
Overview¶
- Device: Siemens PAC2200
- Type: Power Meter
- Protocol: Modbus RTU / Modbus TCP
- Use case: power monitoring, energy metering, and facility automation
- Works with: Modbus Monitor XPF (import directly)
Download Modbus Map¶
The full Siemens PAC2200 Modbus register map is available inside Modbus Monitor XPF as a pre-built device map. Download the free feature-locked version to access and export the complete map.
Register Table (Sample)¶
Sample registers from the Siemens PAC2200 Modbus map. Import the full map in Modbus Monitor XPF to access all registers.
| Signal | Address | Type | Units | Category |
|---|---|---|---|---|
| Voltage UL1 N | 400002 | FLOAT32 | V | Voltage |
| Current L1 | 400014 | FLOAT32 | A | Current |
| Apparent power L1 | 400020 | FLOAT32 | kW | Power |
| Secondary total of active energy im port | 400962 | DOUBLE64 | kWh | Energy |
| Frequency | 400056 | FLOAT32 | Hz | Frequency |
| Device diagnostics and device status | 400206 | UINT32 | - | Status |
| Active tariff | 400212 | UINT32 | - | General |
| Voltage UL2 N | 400004 | FLOAT32 | V | Voltage |
| Voltage UL3 N | 400006 | FLOAT32 | V | Voltage |
| Voltage UL1 L2 | 400008 | FLOAT32 | V | Voltage |
| Voltage UL2 L3 | 400010 | FLOAT32 | V | Voltage |
| Voltage UL3 L1 | 400012 | FLOAT32 | V | Voltage |
How to Use This Map¶
- Download Modbus Monitor XPF — Get the free version.
- Select the Siemens PAC2200 device map — pre-built maps are bundled and ready to load.
- Connect to your device — enter the device IP or COM port and start polling registers immediately.
- Visualise and log — build dashboards, trend data, and export readings without manual register entry.
Why Use Pre-Built Maps¶
- Saves time — no need to manually look up or enter register addresses
- Reduces errors — pre-validated maps eliminate mis-typed addresses and wrong data types
- Speeds commissioning — connect and poll within minutes instead of hours
- Reusable across projects — use the same map across multiple sites and installations
Data Categories Available¶
- Power
- Current
- Voltage
- Energy
- Status
- Frequency
Related Tools¶
- Modbus Monitor XPF — Windows Modbus Tool
- Modbus HMI Builder
- Compare Modbus Monitor XPF with Other Tools