The Schneider Electric PM200P is a power meter used for power monitoring, energy metering, and facility automation. This page provides a sample Modbus register map with addresses, data types, and signal categories to help engineers commission, troubleshoot, and monitor the device. For Schneider Electric PM200P deployments, teams often use this map to surface power, current, and voltage data in data centers, switchgear lineups, and advanced power monitoring projects.

This page shows a preview subset of the full device map available in Modbus Monitor XPF.

Engineers searching for Schneider Electric PM200P Modbus map, Schneider Electric PM200P register map, or Schneider Electric PM200P Modbus registers can use this page as a compatibility snapshot before importing the full map into Modbus Monitor XPF.

Overview

  • Device: Schneider Electric PM200P
  • Type: Power Meter
  • Protocol: Modbus RTU / Modbus TCP
  • Use case: power monitoring, energy metering, and facility automation
  • Works with: Modbus Monitor XPF (import directly)

Download Modbus Map

The full Schneider Electric PM200P Modbus register map is available inside Modbus Monitor XPF as a pre-built device map. Download the free feature-locked version to access and export the complete map.

Register Table (Sample)

Sample registers from the Schneider Electric PM200P Modbus map. Import the full map in Modbus Monitor XPF to access all registers.

Signal Address Type Units Category
Scale Factor V voltage 404106 INT16 V Voltage
Scale Factor I current 404105 INT16 - Current
Scale Factor W power 404107 INT16 kW Power
Scale Factor E energy 404108 INT16 kWh Energy
Service Frequency 404125 INT16 Hz Frequency
Thermal Demand Interval 404117 INT16 kW Demand
Error Bitmap 404112 INT16 - General
Serial Number 407002 UINT16 - Identification
Modbus Address 407005 INT16 - Communication
Power Block Demand Interval 404118 INT16 kW Power
Power Block Demand Number of SubIntervals 404119 INT16 kW Power
Signed Real Energy Consumption 401000 FLOAT kWh Energy

How to Use This Map

  1. Download Modbus Monitor XPFGet the free version.
  2. Select the Schneider Electric PM200P device map — pre-built maps are bundled and ready to load.
  3. Connect to your device — enter the device IP or COM port and start polling registers immediately.
  4. Visualise and log — build dashboards, trend data, and export readings without manual register entry.

Why Use Pre-Built Maps

  • Saves time — no need to manually look up or enter register addresses
  • Reduces errors — pre-validated maps eliminate mis-typed addresses and wrong data types
  • Speeds commissioning — connect and poll within minutes instead of hours
  • Reusable across projects — use the same map across multiple sites and installations

Data Categories Available

  • Power
  • Current
  • Voltage
  • Energy
  • Frequency