Schneider Electric ION9000 Modbus Map¶
This Schneider Electric ION9000 Modbus map is supported in Modbus Monitor XPF, allowing engineers to quickly test, monitor, and visualize device data without manual register mapping.
This page shows a preview subset of the full device map available in Modbus Monitor XPF.
For Schneider Electric ION9000 deployments, teams often use this map to surface current, voltage, and power data in data centers, switchgear lineups, and advanced power monitoring projects.
Use This Device Map in Modbus Monitor XPF¶
Start using this device map in minutes - no manual register mapping required.
- Download Modbus Monitor XPF Free Trial
- Compare Modbus Monitor XPF with Other Tools
- Modbus Tester for Windows
Quick Facts¶
- Manufacturer: Schneider Electric
- Model: ION9000
- Device Type: Power Meter
- Protocol: Modbus
- Typical Use: power monitoring, energy metering, and facility automation
- Available in: Modbus Monitor XPF
Why This Map Matters¶
Instead of manually decoding registers and building your setup from scratch, Modbus Monitor XPF provides a pre-built device map to help engineers test, monitor, and visualize data faster.
Browse all XPF device maps for the full library, explore Schneider Electric device maps to compare related models, and use Compare Modbus Monitor XPF with Other Tools when evaluating fit across your stack.
Register Preview¶
| Signal | Address | Type | Units | Category |
|---|---|---|---|---|
| Voltage A B V | 403021 | FLOAT32 | V | Voltage |
| Current A A | 403001 | FLOAT32 | - | Current |
| Active Power A W | 403055 | FLOAT32 | kW | Power |
| Active Energy Delivered Into Load kWh | 402701 | FLOAT32 | kWh | Energy |
| Frequency Hz | 403111 | FLOAT32 | Hz | Frequency |
| Digital Input Status Validity Base Unit | 402401 | UINT16 | - | Status |
| THD V1 10m Mean | 440029 | FLOAT32 | - | Harmonics |
| Meter Name :20 | 400031 | STRING | - | Identification |
| Year year | 401838 | UINT16 | - | General |
| COM1 Baud Rate | 454393 | UINT16 | - | Communication |
| Digital Output Status Validity Base Unit | 402403 | UINT16 | - | Status |
| Setpoint Status Validity | 402421 | UINT16 | - | Status |
Common Data Categories¶
- Current
- Voltage
- Power
- Energy
- Harmonics
- Frequency
Typical Use Cases¶
- Commissioning new devices with a known-good register baseline
- Troubleshooting Modbus communication and addressing issues
- Building HMI dashboards for operational visibility
- Logging device telemetry for analysis and reporting
Related Device Maps¶
- Schneider Electric PM8000 Modbus Map
- Schneider Electric PM5000 / PM5100 / PM5300 Modbus Map
- Schneider Electric PM5500 / PM5560 / PM5580 Modbus Map
- All Schneider Electric Device Maps
- All XPF Device Maps
Use This Device Map in Modbus Monitor XPF¶
Start using this device map in minutes - no manual register mapping required.