Skip to content

Schneider Electric PM8000 Modbus Register Map

The Schneider Electric PM8000 is a power meter used for power monitoring, energy metering, and facility automation. This page provides a sample Modbus register map with addresses, data types, and signal categories to help engineers commission, troubleshoot, and monitor the device. Commonly used in data centers and high-end power monitoring systems.

This page shows a preview subset of the full device map available in Modbus Monitor XPF.

Engineers searching for Schneider Electric PM8000 Modbus map, Schneider Electric PM8000 register map, or Schneider Electric PM8000 Modbus registers can use this page as a compatibility snapshot before importing the full map into Modbus Monitor XPF.

Overview

  • Device: Schneider Electric PM8000
  • Type: Power Meter
  • Protocol: Modbus RTU / Modbus TCP
  • Use case: power monitoring, energy metering, and facility automation
  • Works with: Modbus Monitor XPF (import directly)

Download Modbus Map

The full Schneider Electric PM8000 Modbus register map is available inside Modbus Monitor XPF as a pre-built device map. Download the free feature-locked version to access and export the complete map.

Register Table (Sample)

Sample registers from the Schneider Electric PM8000 Modbus map. Import the full map in Modbus Monitor XPF to access all registers.

Signal Address Type Units Category
Voltage A B V 403020 FLOAT32 V Voltage
Current A A 403000 FLOAT32 - Current
Active power A W 403054 FLOAT32 kW Power
Active energy delivered into load kWh 402700 FLOAT32 kWh Energy
Frequency Hz 403110 FLOAT32 Hz Frequency
Over Demand Act Pwr Last 14320 INT16 kW Demand
Digital input status validity base unit 402400 UINT16 - Status
Thd V1 10m mean 440028 FLOAT32 - Harmonics
Meter name 400030 STRING - Identification
Year year 401837 UINT16 - General
Com1 baud rate 454392 UINT16 - Communication
Digital output status validity base unit 402402 UINT16 - Status

How to Use This Map

  1. Download Modbus Monitor XPFGet the free version.
  2. Select the Schneider Electric PM8000 device map — pre-built maps are bundled and ready to load.
  3. Connect to your device — enter the device IP or COM port and start polling registers immediately.
  4. Visualise and log — build dashboards, trend data, and export readings without manual register entry.

Why Use Pre-Built Maps

  • Saves time — no need to manually look up or enter register addresses
  • Reduces errors — pre-validated maps eliminate mis-typed addresses and wrong data types
  • Speeds commissioning — connect and poll within minutes instead of hours
  • Reusable across projects — use the same map across multiple sites and installations

Data Categories Available

  • Voltage
  • Current
  • Power
  • Demand
  • Energy
  • Harmonics