Skip to content

Schneider Electric PM8000 Modbus Register Map

The Schneider Electric PM8000 is a power meter used for power monitoring, energy metering, and facility automation. This page provides a sample Modbus register map with addresses, data types, and signal categories to help engineers commission, troubleshoot, and monitor the device. Commonly used in data centers and high-end power monitoring systems.

This page shows a public register preview. Check the catalog in your installed XPF version for complete-map availability and licensing.

Confirm the exact model and firmware, address base, register function, word order, scaling and units against the manufacturer manual before polling. This preview does not establish hardware validation.

Overview

  • Device: Schneider Electric PM8000
  • Type: Power Meter
  • Protocol: Confirm the supported transport for the exact device and firmware in the manufacturer manual.
  • Use case: power monitoring, energy metering, and facility automation
  • Works with: Modbus Monitor XPF (import directly)

Download Modbus Map

The sample below is a public preview. Check the catalog in your installed XPF version for current availability, access and licensing.

Public JSON preview · Preview data terms

Register Table (Sample)

Sample registers from the Schneider Electric PM8000 Modbus map. Confirm the sample against the exact device and firmware before use.

Signal Address Type Units Category
Voltage A B V 403020 FLOAT32 V Voltage
Current A A 403000 FLOAT32 - Current
Active power A W 403054 FLOAT32 kW Power
Active energy delivered into load kWh 402700 FLOAT32 kWh Energy
Frequency Hz 403110 FLOAT32 Hz Frequency
Over Demand Act Pwr Last 14320 INT16 kW Demand
Digital input status validity base unit 402400 UINT16 - Status
Thd V1 10m mean 440028 FLOAT32 - Harmonics
Meter name 400030 STRING - Identification
Year year 401837 UINT16 - General
Com1 baud rate 454392 UINT16 - Communication
Digital output status validity base unit 402402 UINT16 - Status

How to Use This Map

  1. Download Modbus Monitor XPF — Get the free version.
  2. Select the Schneider Electric PM8000 device map — check availability and access in the installed application catalog.
  3. Connect to your device — confirm transport, addressing and data types before starting a read operation.
  4. Visualise and log — build dashboards, trend data, and export readings without manual register entry.

Why Use Pre-Built Maps

  • Saves time — no need to manually look up or enter register addresses
  • Reduces errors — reusable maps reduce repeated manual entry; validate addresses and data types for your device
  • Speeds commissioning — connect and poll within minutes instead of hours
  • Reusable across projects — use the same map across multiple sites and installations

Data Categories Available

  • Voltage
  • Current
  • Power
  • Demand
  • Energy
  • Harmonics