Schneider Electric PM8000 Modbus Register Map¶
The Schneider Electric PM8000 is a power meter used for power monitoring, energy metering, and facility automation. This page provides a sample Modbus register map with addresses, data types, and signal categories to help engineers commission, troubleshoot, and monitor the device. Commonly used in data centers and high-end power monitoring systems.
This page shows a preview subset of the full device map available in Modbus Monitor XPF.
Engineers searching for Schneider Electric PM8000 Modbus map, Schneider Electric PM8000 register map, or Schneider Electric PM8000 Modbus registers can use this page as a compatibility snapshot before importing the full map into Modbus Monitor XPF.
Overview¶
- Device: Schneider Electric PM8000
- Type: Power Meter
- Protocol: Modbus RTU / Modbus TCP
- Use case: power monitoring, energy metering, and facility automation
- Works with: Modbus Monitor XPF (import directly)
Download Modbus Map¶
The full Schneider Electric PM8000 Modbus register map is available inside Modbus Monitor XPF as a pre-built device map. Download the free feature-locked version to access and export the complete map.
Register Table (Sample)¶
Sample registers from the Schneider Electric PM8000 Modbus map. Import the full map in Modbus Monitor XPF to access all registers.
| Signal | Address | Type | Units | Category |
|---|---|---|---|---|
| Voltage A B V | 403020 | FLOAT32 | V | Voltage |
| Current A A | 403000 | FLOAT32 | - | Current |
| Active power A W | 403054 | FLOAT32 | kW | Power |
| Active energy delivered into load kWh | 402700 | FLOAT32 | kWh | Energy |
| Frequency Hz | 403110 | FLOAT32 | Hz | Frequency |
| Over Demand Act Pwr Last | 14320 | INT16 | kW | Demand |
| Digital input status validity base unit | 402400 | UINT16 | - | Status |
| Thd V1 10m mean | 440028 | FLOAT32 | - | Harmonics |
| Meter name | 400030 | STRING | - | Identification |
| Year year | 401837 | UINT16 | - | General |
| Com1 baud rate | 454392 | UINT16 | - | Communication |
| Digital output status validity base unit | 402402 | UINT16 | - | Status |
How to Use This Map¶
- Download Modbus Monitor XPF — Get the free version.
- Select the Schneider Electric PM8000 device map — pre-built maps are bundled and ready to load.
- Connect to your device — enter the device IP or COM port and start polling registers immediately.
- Visualise and log — build dashboards, trend data, and export readings without manual register entry.
Why Use Pre-Built Maps¶
- Saves time — no need to manually look up or enter register addresses
- Reduces errors — pre-validated maps eliminate mis-typed addresses and wrong data types
- Speeds commissioning — connect and poll within minutes instead of hours
- Reusable across projects — use the same map across multiple sites and installations
Data Categories Available¶
- Voltage
- Current
- Power
- Demand
- Energy
- Harmonics