Schneider Electric ION8800 Modbus Register Map¶
The Schneider Electric ION8800 is a power meter used for power monitoring, energy metering, and facility automation. This page provides a sample Modbus register map with addresses, data types, and signal categories to help engineers commission, troubleshoot, and monitor the device. For Schneider Electric ION8800 deployments, teams often use this map to surface power, power factor, and energy data in data centers, switchgear lineups, and advanced power monitoring projects.
This page shows a public register preview. Check the catalog in your installed XPF version for complete-map availability and licensing.
Confirm the exact model and firmware, address base, register function, word order, scaling and units against the manufacturer manual before polling. This preview does not establish hardware validation.
Overview¶
- Device: Schneider Electric ION8800
- Type: Power Meter
- Protocol: Confirm the supported transport for the exact device and firmware in the manufacturer manual.
- Use case: power monitoring, energy metering, and facility automation
- Works with: Modbus Monitor XPF (import directly)
Download Modbus Map¶
The sample below is a public preview. Check the catalog in your installed XPF version for current availability, access and licensing.
Public JSON preview · Preview data terms
Register Table (Sample)¶
Sample registers from the Schneider Electric ION8800 Modbus map. Confirm the sample against the exact device and firmware before use.
| Signal | Address | Type | Units | Category |
|---|---|---|---|---|
| Uln 1 VoltsAmpsFreq | 400010 | UINT16 | A | Current |
| kW 1 PowerPF kW | 400026 | INT32 | kW | Power |
| kWh del EnergyTHD kWh | 400090 | INT32 | kWh | Energy |
| I 1 Ampfrequnbal | 400149 | UINT16 | - | Power Factor |
| Ull avg mx MinMaxDemand | 400058 | INT32 | kW | Demand |
| Uln 1 Volts | 400165 | UINT32 | - | General |
| PO U1-Flck N EN50160 Modbus 1 | 400999 | UINT16 | - | Communication |
| Uln 2 VoltsAmpsFreq | 400011 | UINT16 | A | Current |
| Uln 3 VoltsAmpsFreq | 400012 | UINT16 | A | Current |
| Uln avg VoltsAmpsFreq | 400013 | UINT16 | A | Current |
| Ull 12 VoltsAmpsFreq | 400014 | UINT16 | A | Current |
| Ull 23 VoltsAmpsFreq | 400015 | UINT16 | A | Current |
How to Use This Map¶
- Download Modbus Monitor XPF — Get the free version.
- Select the Schneider Electric ION8800 device map — check availability and access in the installed application catalog.
- Connect to your device — confirm transport, addressing and data types before starting a read operation.
- Visualise and log — build dashboards, trend data, and export readings without manual register entry.
Why Use Pre-Built Maps¶
- Saves time — no need to manually look up or enter register addresses
- Reduces errors — reusable maps reduce repeated manual entry; validate addresses and data types for your device
- Speeds commissioning — connect and poll within minutes instead of hours
- Reusable across projects — use the same map across multiple sites and installations
Data Categories Available¶
- Power
- Power Factor
- Energy
- Current
- Demand
Related Tools¶
- Modbus Monitor XPF — Windows Modbus Tool
- Modbus HMI Builder
- Compare Modbus Monitor XPF with Other Tools