Schneider Electric ION7500 / ION7550 Modbus Register Map

The Schneider Electric ION7500 / ION7550 is a power meter used for power monitoring, energy metering, and facility automation. This page provides a sample Modbus register map with addresses, data types, and signal categories to help engineers commission, troubleshoot, and monitor the device. For Schneider Electric ION7500 / ION7550 deployments, teams often use this map to surface power, energy, and power factor data in data centers, switchgear lineups, and advanced power monitoring projects.

This page shows a public register preview. Check the catalog in your installed XPF version for complete-map availability and licensing.

Confirm the exact model and firmware, address base, register function, word order, scaling and units against the manufacturer manual before polling. This preview does not establish hardware validation.

Overview

  • Device: Schneider Electric ION7500 / ION7550
  • Type: Power Meter
  • Protocol: Confirm the supported transport for the exact device and firmware in the manufacturer manual.
  • Use case: power monitoring, energy metering, and facility automation
  • Works with: Modbus Monitor XPF (import directly)

Download Modbus Map

The sample below is a public preview. Check the catalog in your installed XPF version for current availability, access and licensing.

Public JSON preview · Preview data terms

Register Table (Sample)

Sample registers from the Schneider Electric ION7500 / ION7550 Modbus map. Confirm the sample against the exact device and firmware before use.

Signal Address Type Units Category
Vln a VoltsAmpsFreq 1 400010 UINT16 A Current
kW a 400198 INT32 - Power
kWh del 400230 INT32 kWh Energy
PF sign a 400262 INT16 - Power Factor
Vll avg mx MinMaxDemand 3 400058 INT32 kW Demand
V1 THD mx 400266 INT16 - Harmonics
I a 400150 UINT16 - General
PO V1-Flck N EN50160 Modbus1 400999 UINT16 - Communication
kW b 400200 INT32 - Power
kW c 400202 INT32 - Power
kW tot 400204 INT32 - Power
kW tot mx 400206 INT32 - Power

How to Use This Map

  1. Download Modbus Monitor XPF — Get the free version.
  2. Select the Schneider Electric ION7500 / ION7550 device map — check availability and access in the installed application catalog.
  3. Connect to your device — confirm transport, addressing and data types before starting a read operation.
  4. Visualise and log — build dashboards, trend data, and export readings without manual register entry.

Why Use Pre-Built Maps

  • Saves time — no need to manually look up or enter register addresses
  • Reduces errors — reusable maps reduce repeated manual entry; validate addresses and data types for your device
  • Speeds commissioning — connect and poll within minutes instead of hours
  • Reusable across projects — use the same map across multiple sites and installations

Data Categories Available

  • Power
  • Energy
  • Power Factor
  • Current
  • Demand
  • Harmonics