Schneider Electric ION7500 / ION7550 Modbus Register Map

The Schneider Electric ION7500 / ION7550 is a power meter used for power monitoring, energy metering, and facility automation. This page provides a sample Modbus register map with addresses, data types, and signal categories to help engineers commission, troubleshoot, and monitor the device. For Schneider Electric ION7500 / ION7550 deployments, teams often use this map to surface power, energy, and power factor data in data centers, switchgear lineups, and advanced power monitoring projects.

This page shows a preview subset of the full device map available in Modbus Monitor XPF.

Engineers searching for Schneider Electric ION7500 / ION7550 Modbus map, Schneider Electric ION7500 / ION7550 register map, or Schneider Electric ION7500 / ION7550 Modbus registers can use this page as a compatibility snapshot before importing the full map into Modbus Monitor XPF.

Overview

  • Device: Schneider Electric ION7500 / ION7550
  • Type: Power Meter
  • Protocol: Modbus RTU / Modbus TCP
  • Use case: power monitoring, energy metering, and facility automation
  • Works with: Modbus Monitor XPF (import directly)

Download Modbus Map

The full Schneider Electric ION7500 / ION7550 Modbus register map is available inside Modbus Monitor XPF as a pre-built device map. Download the free feature-locked version to access and export the complete map.

Register Table (Sample)

Sample registers from the Schneider Electric ION7500 / ION7550 Modbus map. Import the full map in Modbus Monitor XPF to access all registers.

Signal Address Type Units Category
Vln a VoltsAmpsFreq 1 400010 UINT16 A Current
kW a 400198 INT32 - Power
kWh del 400230 INT32 kWh Energy
PF sign a 400262 INT16 - Power Factor
Vll avg mx MinMaxDemand 3 400058 INT32 kW Demand
V1 THD mx 400266 INT16 - Harmonics
I a 400150 UINT16 - General
PO V1-Flck N EN50160 Modbus1 400999 UINT16 - Communication
kW b 400200 INT32 - Power
kW c 400202 INT32 - Power
kW tot 400204 INT32 - Power
kW tot mx 400206 INT32 - Power

How to Use This Map

  1. Download Modbus Monitor XPFGet the free version.
  2. Select the Schneider Electric ION7500 / ION7550 device map — pre-built maps are bundled and ready to load.
  3. Connect to your device — enter the device IP or COM port and start polling registers immediately.
  4. Visualise and log — build dashboards, trend data, and export readings without manual register entry.

Why Use Pre-Built Maps

  • Saves time — no need to manually look up or enter register addresses
  • Reduces errors — pre-validated maps eliminate mis-typed addresses and wrong data types
  • Speeds commissioning — connect and poll within minutes instead of hours
  • Reusable across projects — use the same map across multiple sites and installations

Data Categories Available

  • Power
  • Energy
  • Power Factor
  • Current
  • Demand
  • Harmonics