Schneider Electric iEM3000 Modbus Register Map

The Schneider Electric iEM3000 is a power meter used for power monitoring, energy metering, and facility automation. This page provides a sample Modbus register map with addresses, data types, and signal categories to help engineers commission, troubleshoot, and monitor the device. For Schneider Electric iEM3000 deployments, teams often use this map to surface energy, power, and current data in data centers, switchgear lineups, and advanced power monitoring projects.

This page shows a preview subset of the full device map available in Modbus Monitor XPF.

Engineers searching for Schneider Electric iEM3000 Modbus map, Schneider Electric iEM3000 register map, or Schneider Electric iEM3000 Modbus registers can use this page as a compatibility snapshot before importing the full map into Modbus Monitor XPF.

Overview

  • Device: Schneider Electric iEM3000
  • Type: Power Meter
  • Protocol: Modbus RTU / Modbus TCP
  • Use case: power monitoring, energy metering, and facility automation
  • Works with: Modbus Monitor XPF (import directly)

Download Modbus Map

The full Schneider Electric iEM3000 Modbus register map is available inside Modbus Monitor XPF as a pre-built device map. Download the free feature-locked version to access and export the complete map.

Register Table (Sample)

Sample registers from the Schneider Electric iEM3000 Modbus map. Import the full map in Modbus Monitor XPF to access all registers.

Signal Address Type Units Category
Voltage L1 L2 V 403020 FLOAT32 V Voltage
I1 phase 1 current A 403000 FLOAT32 - Current
Active power phase 1 kW 403054 FLOAT32 kW Power
Total active energy import Wh 403204 INT64 kWh Energy
Frequency Hz 403110 FLOAT32 Hz Frequency
Demand method 403701 UINT16 kW Demand
Digital input status bit only bit 1 is used 408905 UINT16 - Status
Digital input control mode 407274 UINT16 - General
MeterName:20 400029 STRING - Identification
Protocol 0Modbus 406499 INT16 - Communication
Digital output control mode status 409673 UINT16 - Status
I2 phase 2 current A 403002 FLOAT32 - Current

How to Use This Map

  1. Download Modbus Monitor XPFGet the free version.
  2. Select the Schneider Electric iEM3000 device map — pre-built maps are bundled and ready to load.
  3. Connect to your device — enter the device IP or COM port and start polling registers immediately.
  4. Visualise and log — build dashboards, trend data, and export readings without manual register entry.

Why Use Pre-Built Maps

  • Saves time — no need to manually look up or enter register addresses
  • Reduces errors — pre-validated maps eliminate mis-typed addresses and wrong data types
  • Speeds commissioning — connect and poll within minutes instead of hours
  • Reusable across projects — use the same map across multiple sites and installations

Data Categories Available

  • Energy
  • Power
  • Current
  • Voltage
  • Status
  • Demand