Schneider Electric EM7290 Modbus Register Map

The Schneider Electric EM7290 is a power meter used for power monitoring, energy metering, and facility automation. This page provides a sample Modbus register map with addresses, data types, and signal categories to help engineers commission, troubleshoot, and monitor the device. For Schneider Electric EM7290 deployments, teams often use this map to surface demand, voltage, and energy data in data centers, switchgear lineups, and advanced power monitoring projects.

This page shows a preview subset of the full device map available in Modbus Monitor XPF.

Engineers searching for Schneider Electric EM7290 Modbus map, Schneider Electric EM7290 register map, or Schneider Electric EM7290 Modbus registers can use this page as a compatibility snapshot before importing the full map into Modbus Monitor XPF.

Overview

  • Device: Schneider Electric EM7290
  • Type: Power Meter
  • Protocol: Modbus RTU / Modbus TCP
  • Use case: power monitoring, energy metering, and facility automation
  • Works with: Modbus Monitor XPF (import directly)

Download Modbus Map

The full Schneider Electric EM7290 Modbus register map is available inside Modbus Monitor XPF as a pre-built device map. Download the free feature-locked version to access and export the complete map.

Register Table (Sample)

Sample registers from the Schneider Electric EM7290 Modbus map. Import the full map in Modbus Monitor XPF to access all registers.

Signal Address Type Units Category
Max Voltage L L Avg 402309 FLOAT32 V Voltage
Starting current 400999 UINT16 - Current
Number of Control Power Failures 401828 UINT16 kW Power
Energy LED Mode 402125 UINT16 kWh Energy
Nominal Frequency 402016 UINT16 Hz Frequency
PF standard 401000 UINT16 - Power Factor
Demand Method 401006 UINT16 kW Demand
Revenue Security Status 401920 UINT16 - Status
Meter Name:20 400029 STRING - Identification
Manufacturer:20 400069 STRING - General
Supported Features 400094 UINT16 - Communication
PF Lock 401002 UINT16 - Power Factor

How to Use This Map

  1. Download Modbus Monitor XPFGet the free version.
  2. Select the Schneider Electric EM7290 device map — pre-built maps are bundled and ready to load.
  3. Connect to your device — enter the device IP or COM port and start polling registers immediately.
  4. Visualise and log — build dashboards, trend data, and export readings without manual register entry.

Why Use Pre-Built Maps

  • Saves time — no need to manually look up or enter register addresses
  • Reduces errors — pre-validated maps eliminate mis-typed addresses and wrong data types
  • Speeds commissioning — connect and poll within minutes instead of hours
  • Reusable across projects — use the same map across multiple sites and installations

Data Categories Available

  • Demand
  • Voltage
  • Energy
  • Current
  • Power
  • Power Factor