Eaton PXM4000 Modbus Register Map

The Eaton PXM4000 is a power meter used for power monitoring, energy metering, and facility automation. This page provides a sample Modbus register map with addresses, data types, and signal categories to help engineers commission, troubleshoot, and monitor the device. For Eaton PXM4000 deployments, teams often use this map to surface demand, power factor, and status data in critical power distribution and electrical monitoring systems.

This page shows a public register preview. Check the catalog in your installed XPF version for complete-map availability and licensing.

Confirm the exact model and firmware, address base, register function, word order, scaling and units against the manufacturer manual before polling. This preview does not establish hardware validation.

Overview

  • Device: Eaton PXM4000
  • Type: Power Meter
  • Protocol: Confirm the supported transport for the exact device and firmware in the manufacturer manual.
  • Use case: power monitoring, energy metering, and facility automation
  • Works with: Modbus Monitor XPF (import directly)

Download Modbus Map

The sample below is a public preview. Check the catalog in your installed XPF version for current availability, access and licensing.

Public JSON preview · Preview data terms

Register Table (Sample)

Sample registers from the Eaton PXM4000 Modbus map. Confirm the sample against the exact device and firmware before use.

Signal Address Type Units Category
DemandAmpsAvg 414112 FLOAT32 A Current
ForwardEnergy 406305 FLOAT32 kWh Energy
PFdisplacementTotal 404657 FLOAT32 - Power Factor
DemandForwardWatts 414114 FLOAT32 kW Demand
SecondaryStatus 404609 UINT32 - Status
ErrCode 404610 UINT32 - General
Status 404609 UINT32 - Status
PFapparentTotal 404659 FLOAT32 - Power Factor
PFdisplacementA 404685 FLOAT32 - Power Factor
PFdisplacementB 404687 FLOAT32 - Power Factor
PFdisplacementC 404689 FLOAT32 - Power Factor
PFapparentA 404691 FLOAT32 - Power Factor

How to Use This Map

  1. Download Modbus Monitor XPF — Get the free version.
  2. Select the Eaton PXM4000 device map — check availability and access in the installed application catalog.
  3. Connect to your device — confirm transport, addressing and data types before starting a read operation.
  4. Visualise and log — build dashboards, trend data, and export readings without manual register entry.

Why Use Pre-Built Maps

  • Saves time — no need to manually look up or enter register addresses
  • Reduces errors — reusable maps reduce repeated manual entry; validate addresses and data types for your device
  • Speeds commissioning — connect and poll within minutes instead of hours
  • Reusable across projects — use the same map across multiple sites and installations

Data Categories Available

  • Demand
  • Power Factor
  • Status
  • Energy
  • Current