Eaton BladeUPS Modbus Map

This Eaton BladeUPS Modbus map is supported in Modbus Monitor XPF, allowing engineers to quickly test, monitor, and visualize device data without manual register mapping.

This page shows a preview subset of the full device map available in Modbus Monitor XPF.

For Eaton BladeUPS deployments, teams often use this map to surface voltage, status, and power data in UPS infrastructure, backup power systems, and resilience programs.

Use This Device Map in Modbus Monitor XPF

Start using this device map in minutes - no manual register mapping required.

Quick Facts

  • Manufacturer: Eaton
  • Model: BladeUPS
  • Device Type: UPS
  • Protocol: Modbus
  • Typical Use: power continuity monitoring, alarm review, and resilience planning
  • Available in: Modbus Monitor XPF

Why This Map Matters

Instead of manually decoding registers and building your setup from scratch, Modbus Monitor XPF provides a pre-built device map to help engineers test, monitor, and visualize data faster.

Browse all XPF device maps for the full library, explore Eaton device maps to compare related models, and use Compare Modbus Monitor XPF with Other Tools when evaluating fit across your stack.

Register Preview

Signal Address Type Units Category
Nominal Input Voltage iDeviceVoltsInRatingValue 301358 UINT32 V Voltage
Output Current Rating iDeviceAmpsRatingValue 301811 UINT16 A Current
Power Strategy sPowerStrategyValue 303004 UINT16 kW Power
Output KW Hours mOutputKWHourValue 307003 FLOAT32 kWh Energy
Nominal Input Frequency iNominalInputFrequencyValue 301670 UINT16 Hz Frequency
Min Battery Capacity for Return iMinBattCapforReturnValue 318490 UINT16 - Power Factor
Low Runtime Alarm Setpoint iLowRuntimeSetpointValue 301676 UINT16 - Status
Ambient Temperature mTempAmbientValue 312001 FLOAT32 degC Temperature
Vendor Name VendorNameValue:32 301033 STRING - Identification
Device Type iDeviceTypeValue:32 301129 STRING - General
Nominal Output Voltage iDeviceVoltsOutRatingValue 301360 UINT32 V Voltage
Nominal Output Frequency iNominalOutputFrequencyValue 301671 UINT16 Hz Frequency

Common Data Categories

  • Voltage
  • Status
  • Power
  • Frequency
  • Current
  • Temperature

Typical Use Cases

  • Commissioning new devices with a known-good register baseline
  • Troubleshooting Modbus communication and addressing issues
  • Building HMI dashboards for operational visibility
  • Logging device telemetry for analysis and reporting