Eaton BladeUPS Modbus Register Map

The Eaton BladeUPS is a ups used for power continuity monitoring, alarm review, and resilience planning. This page provides a sample Modbus register map with addresses, data types, and signal categories to help engineers commission, troubleshoot, and monitor the device. For Eaton BladeUPS deployments, teams often use this map to surface voltage, status, and power data in UPS infrastructure, backup power systems, and resilience programs.

This page shows a preview subset of the full device map available in Modbus Monitor XPF.

Engineers searching for Eaton BladeUPS Modbus map, Eaton BladeUPS register map, or Eaton BladeUPS Modbus registers can use this page as a compatibility snapshot before importing the full map into Modbus Monitor XPF.

Overview

  • Device: Eaton BladeUPS
  • Type: UPS
  • Protocol: Modbus RTU / Modbus TCP
  • Use case: power continuity monitoring, alarm review, and resilience planning
  • Works with: Modbus Monitor XPF (import directly)

Download Modbus Map

The full Eaton BladeUPS Modbus register map is available inside Modbus Monitor XPF as a pre-built device map. Download the free feature-locked version to access and export the complete map.

Register Table (Sample)

Sample registers from the Eaton BladeUPS Modbus map. Import the full map in Modbus Monitor XPF to access all registers.

Signal Address Type Units Category
Nominal Input Voltage iDeviceVoltsInRatingValue 301358 UINT32 V Voltage
Output Current Rating iDeviceAmpsRatingValue 301811 UINT16 A Current
Power Strategy sPowerStrategyValue 303004 UINT16 kW Power
Output KW Hours mOutputKWHourValue 307003 FLOAT32 kWh Energy
Nominal Input Frequency iNominalInputFrequencyValue 301670 UINT16 Hz Frequency
Min Battery Capacity for Return iMinBattCapforReturnValue 318490 UINT16 - Power Factor
Low Runtime Alarm Setpoint iLowRuntimeSetpointValue 301676 UINT16 - Status
Ambient Temperature mTempAmbientValue 312001 FLOAT32 degC Temperature
Vendor Name VendorNameValue:32 301033 STRING - Identification
Device Type iDeviceTypeValue:32 301129 STRING - General
Nominal Output Voltage iDeviceVoltsOutRatingValue 301360 UINT32 V Voltage
Nominal Output Frequency iNominalOutputFrequencyValue 301671 UINT16 Hz Frequency

How to Use This Map

  1. Download Modbus Monitor XPFGet the free version.
  2. Select the Eaton BladeUPS device map — pre-built maps are bundled and ready to load.
  3. Connect to your device — enter the device IP or COM port and start polling registers immediately.
  4. Visualise and log — build dashboards, trend data, and export readings without manual register entry.

Why Use Pre-Built Maps

  • Saves time — no need to manually look up or enter register addresses
  • Reduces errors — pre-validated maps eliminate mis-typed addresses and wrong data types
  • Speeds commissioning — connect and poll within minutes instead of hours
  • Reusable across projects — use the same map across multiple sites and installations

Data Categories Available

  • Voltage
  • Status
  • Power
  • Frequency
  • Current
  • Temperature