Eaton EM19 M Modbus Register Map

The Eaton EM19 M is a power meter used for power monitoring, energy metering, and facility automation. This page provides a sample Modbus register map with addresses, data types, and signal categories to help engineers commission, troubleshoot, and monitor the device. For Eaton EM19 M deployments, teams often use this map to surface demand, harmonics, and power factor data in critical power distribution and electrical monitoring systems.

This page shows a public register preview. Check the catalog in your installed XPF version for complete-map availability and licensing.

Confirm the exact model and firmware, address base, register function, word order, scaling and units against the manufacturer manual before polling. This preview does not establish hardware validation.

Overview

  • Device: Eaton EM19 M
  • Type: Power Meter
  • Protocol: Confirm the supported transport for the exact device and firmware in the manufacturer manual.
  • Use case: power monitoring, energy metering, and facility automation
  • Works with: Modbus Monitor XPF (import directly)

Download Modbus Map

The sample below is a public preview. Check the catalog in your installed XPF version for current availability, access and licensing.

Public JSON preview · Preview data terms

Register Table (Sample)

Sample registers from the Eaton EM19 M Modbus map. Confirm the sample against the exact device and firmware before use.

Signal Address Type Units Category
ForwardEnergy 400515 FLOAT32 kWh Energy
PFapparentA 407699 FLOAT32 - Power Factor
PwrDemandWindowPeriod 403336 FLOAT32 kW Demand
VanPerTHD 404353 FLOAT32 - Harmonics
VAh 400517 FLOAT32 - General
ReverseEnergy 400525 FLOAT32 kWh Energy
CurDemandWindowPeriod 403594 FLOAT32 kW Demand
ACIAPeakDemand 403841 FLOAT32 kW Demand
ACIBPeakDemand 403842 FLOAT32 kW Demand
ACICPeakDemand 403843 FLOAT32 kW Demand
DemandACVanPeak 403844 FLOAT32 kW Demand
DemandACVbnPeak 403845 FLOAT32 kW Demand

How to Use This Map

  1. Download Modbus Monitor XPF — Get the free version.
  2. Select the Eaton EM19 M device map — check availability and access in the installed application catalog.
  3. Connect to your device — confirm transport, addressing and data types before starting a read operation.
  4. Visualise and log — build dashboards, trend data, and export readings without manual register entry.

Why Use Pre-Built Maps

  • Saves time — no need to manually look up or enter register addresses
  • Reduces errors — reusable maps reduce repeated manual entry; validate addresses and data types for your device
  • Speeds commissioning — connect and poll within minutes instead of hours
  • Reusable across projects — use the same map across multiple sites and installations

Data Categories Available

  • Demand
  • Harmonics
  • Power Factor
  • Energy