Eaton EM22-DIN Modbus Register Map

The Eaton EM22-DIN is a power meter used for power monitoring, energy metering, and facility automation. This page provides a sample Modbus register map with addresses, data types, and signal categories to help engineers commission, troubleshoot, and monitor the device. For Eaton EM22-DIN deployments, teams often use this map to surface demand and energy data in critical power distribution and electrical monitoring systems.

This page shows a preview subset of the full device map available in Modbus Monitor XPF.

Engineers searching for Eaton EM22-DIN Modbus map, Eaton EM22-DIN register map, or Eaton EM22-DIN Modbus registers can use this page as a compatibility snapshot before importing the full map into Modbus Monitor XPF.

Overview

  • Device: Eaton EM22-DIN
  • Type: Power Meter
  • Protocol: Modbus RTU / Modbus TCP
  • Use case: power monitoring, energy metering, and facility automation
  • Works with: Modbus Monitor XPF (import directly)

Download Modbus Map

The full Eaton EM22-DIN Modbus register map is available inside Modbus Monitor XPF as a pre-built device map. Download the free feature-locked version to access and export the complete map.

Register Table (Sample)

Sample registers from the Eaton EM22-DIN Modbus map. Import the full map in Modbus Monitor XPF to access all registers.

Signal Address Type Units Category
TotalEnergy 400035 FLOAT32 kWh Energy
DemandTotalWatts 400027 FLOAT32 kW Demand
ACVAN 400001 FLOAT32 - General
PeakDemandWatts 400029 FLOAT32 kW Demand
DemandVAs 400031 FLOAT32 kW Demand
PeakDemandVAs 400033 FLOAT32 kW Demand
TotalEnergyA 400037 FLOAT32 kWh Energy
TotalEnergyB 400039 FLOAT32 kWh Energy
DemandWindow 404357 UINT16 kW Demand
ACIout1A 400003 FLOAT32 - General
ACIout2A 400005 FLOAT32 - General
ACIA 400007 FLOAT32 - General

How to Use This Map

  1. Download Modbus Monitor XPFGet the free version.
  2. Select the Eaton EM22-DIN device map — pre-built maps are bundled and ready to load.
  3. Connect to your device — enter the device IP or COM port and start polling registers immediately.
  4. Visualise and log — build dashboards, trend data, and export readings without manual register entry.

Why Use Pre-Built Maps

  • Saves time — no need to manually look up or enter register addresses
  • Reduces errors — pre-validated maps eliminate mis-typed addresses and wrong data types
  • Speeds commissioning — connect and poll within minutes instead of hours
  • Reusable across projects — use the same map across multiple sites and installations

Data Categories Available

  • Demand
  • Energy