Skip to content

Socomec Multis L20, Multis L40 Modbus Register Map

The Socomec Multis L20, Multis L40 is a power meter used for power monitoring, energy metering, and facility automation. This page provides a sample Modbus register map with addresses, data types, and signal categories to help engineers commission, troubleshoot, and monitor the device. For Socomec Multis L20, Multis L40 deployments, teams often use this map to surface power, voltage, and current data in facility metering, commissioning, and operational analytics.

This page shows a public register preview. Check the catalog in your installed XPF version for complete-map availability and licensing.

Confirm the exact model and firmware, address base, register function, word order, scaling and units against the manufacturer manual before polling. This preview does not establish hardware validation.

Overview

  • Device: Socomec Multis L20, Multis L40
  • Type: Power Meter
  • Protocol: Confirm the supported transport for the exact device and firmware in the manufacturer manual.
  • Use case: power monitoring, energy metering, and facility automation
  • Works with: Modbus Monitor XPF (import directly)

Download Modbus Map

The sample below is a public preview. Check the catalog in your installed XPF version for current availability, access and licensing.

Public JSON preview · Preview data terms

Register Table (Sample)

Sample registers from the Socomec Multis L20, Multis L40 Modbus map. Confirm the sample against the exact device and firmware before use.

Signal Address Type Units Category
Voltage L1 V 400000 UINT32 V Voltage
Current L1 A 400006 UINT32 A Current
Active power L1 W 400020 INT32 kW Power
Import active energy 1 Wh 400086 INT64 kWh Energy
Frequency Hz 400058 INT32 Hz Frequency
Average inductive CosF Var 400054 INT32 - General
Voltage L2 V 400002 UINT32 V Voltage
Voltage L3 V 400004 UINT32 V Voltage
Current L2 A 400008 UINT32 A Current
Current L3 A 400010 UINT32 A Current
Current L-N A 400012 UINT32 A Current
Voltage L1-L2 V 400014 UINT32 V Voltage

How to Use This Map

  1. Download Modbus Monitor XPF — Get the free version.
  2. Select the Socomec Multis L20, Multis L40 device map — check availability and access in the installed application catalog.
  3. Connect to your device — confirm transport, addressing and data types before starting a read operation.
  4. Visualise and log — build dashboards, trend data, and export readings without manual register entry.

Why Use Pre-Built Maps

  • Saves time — no need to manually look up or enter register addresses
  • Reduces errors — reusable maps reduce repeated manual entry; validate addresses and data types for your device
  • Speeds commissioning — connect and poll within minutes instead of hours
  • Reusable across projects — use the same map across multiple sites and installations

Data Categories Available

  • Power
  • Voltage
  • Current
  • Energy
  • Frequency