Skip to content

Socomec Countis ECI2 Modbus Register Map

The Socomec Countis ECI2 is a power meter used for power monitoring, energy metering, and facility automation. This page provides a sample Modbus register map with addresses, data types, and signal categories to help engineers commission, troubleshoot, and monitor the device. For Socomec Countis ECI2 deployments, teams often use this map to surface current, frequency, and status data in facility metering, commissioning, and operational analytics.

This page shows a public register preview. Check the catalog in your installed XPF version for complete-map availability and licensing.

Confirm the exact model and firmware, address base, register function, word order, scaling and units against the manufacturer manual before polling. This preview does not establish hardware validation.

Overview

  • Device: Socomec Countis ECI2
  • Type: Power Meter
  • Protocol: Confirm the supported transport for the exact device and firmware in the manufacturer manual.
  • Use case: power monitoring, energy metering, and facility automation
  • Works with: Modbus Monitor XPF (import directly)

Download Modbus Map

The sample below is a public preview. Check the catalog in your installed XPF version for current availability, access and licensing.

Public JSON preview · Preview data terms

Register Table (Sample)

Sample registers from the Socomec Countis ECI2 Modbus map. Confirm the sample against the exact device and firmware before use.

Signal Address Type Units Category
Date & Time Current s 437120 UINT16 - Current
Custom Meter Frequency 439698 UINT16 Hz Frequency
Status 440981 UINT16 - Status
Label of custom unit :2 437072 STRING - General
Name :5 440192 STRING - Identification
Address 440448 UINT16 - Communication
Custom Meter Frequency 439725 UINT16 Hz Frequency
Custom Meter Frequency 439752 UINT16 Hz Frequency
Custom Meter Frequency 439779 UINT16 Hz Frequency
Custom Meter Frequency 439806 UINT16 Hz Frequency
Custom Meter Frequency 439833 UINT16 Hz Frequency
Custom Meter Frequency 439860 UINT16 Hz Frequency

How to Use This Map

  1. Download Modbus Monitor XPF — Get the free version.
  2. Select the Socomec Countis ECI2 device map — check availability and access in the installed application catalog.
  3. Connect to your device — confirm transport, addressing and data types before starting a read operation.
  4. Visualise and log — build dashboards, trend data, and export readings without manual register entry.

Why Use Pre-Built Maps

  • Saves time — no need to manually look up or enter register addresses
  • Reduces errors — reusable maps reduce repeated manual entry; validate addresses and data types for your device
  • Speeds commissioning — connect and poll within minutes instead of hours
  • Reusable across projects — use the same map across multiple sites and installations

Data Categories Available

  • Current
  • Frequency
  • Status
Public catalog sample

The public JSON sample differs from the guide table above. Both are previews; confirm the exact model and firmware before use.

SignalDisplay addressData typeUnitsCategory
Pulse meter current custom time437139UINT32-Current
Unit 0 wh 1 varh 2 VAh 3 M3 4 NM3 5 J 6 imp 7 L 8 custom unit 10 kWh 11 kvarh 12 kVAh 13 KM3 14 kNm3 15 kJ 16 k-imp439690UINT16kWhEnergy
Custom meter frequency 0 daily 1 weekly 2 monthly 3 yearly 4 non cyclic439698UINT16HzFrequency
Mode 0 disabled 1 logical state 2 analogical value 3 combination440197UINT16-Status
Label of custom unit437072STRING-General
Name440192STRING-Identification
Logical mode 0 low state 1 high state 2 falling edge 3 rising edge 4 both falling and rising edge440201UINT16-Status
Mode 0 disabled 1 logical state 2 analogical value 3 combination440214UINT16-Status
Logical mode 0 low state 1 high state 2 falling edge 3 rising edge 4 both falling and rising edge440218UINT16-Status
Mode 0 disabled 1 logical state 2 analogical value 3 combination440231UINT16-Status
Logical mode 0 low state 1 high state 2 falling edge 3 rising edge 4 both falling and rising edge440235UINT16-Status
Mode 0 disabled 1 logical state 2 analogical value 3 combination440248UINT16-Status