Skip to content

Socomec Countis E13 Modbus Register Map

The Socomec Countis E13 is a power meter used for power monitoring, energy metering, and facility automation. This page provides a sample Modbus register map with addresses, data types, and signal categories to help engineers commission, troubleshoot, and monitor the device. For Socomec Countis E13 deployments, teams often use this map to surface energy, power, and voltage data in facility metering, commissioning, and operational analytics.

This page shows a preview subset of the full device map available in Modbus Monitor XPF.

Engineers searching for Socomec Countis E13 Modbus map, Socomec Countis E13 register map, or Socomec Countis E13 Modbus registers can use this page as a compatibility snapshot before importing the full map into Modbus Monitor XPF. Also aligns to search intent around Socomec Countis E13 Modbus register list, Socomec Countis E13 Modbus table.

Overview

  • Device: Socomec Countis E13
  • Type: Power Meter
  • Protocol: Modbus RTU / Modbus TCP
  • Use case: power monitoring, energy metering, and facility automation
  • Works with: Modbus Monitor XPF (import directly)

Download Modbus Map

The full Socomec Countis E13 Modbus register map is available inside Modbus Monitor XPF as a pre-built device map. Download the free feature-locked version to access and export the complete map.

Register Table (Sample)

Sample registers from the Socomec Countis E13 Modbus map. Import the full map in Modbus Monitor XPF to access all registers.

Signal Address Type Units Category
Simple voltage V1 V 450520 UINT32 V Voltage
Current I1 A 450528 UINT32 - Current
Sum Active Power P P W 450536 INT32 kW Power
Partial Positive Active Energy EaP Wh 450780 UINT32 kWh Energy
Frequency F Hz 450526 UINT32 Hz Frequency
MID status 0 non MID product 1 MID product 440545 UINT16 - Status
SOCO :4 450000 STRING - General
JBUS Table Version EX 101 Version 1 01 450006 UINT16 - Identification
Slave Address 457344 UINT16 - Communication
Sum Reactive Power P Q var 450538 INT32 kW Power
Sum Apparent Power S VA 450540 UINT32 kW Power
Sum Power Factor leading et P lagging PF 450542 INT32 PF Power

How to Use This Map

  1. Download Modbus Monitor XPFGet the free version.
  2. Select the Socomec Countis E13 device map — pre-built maps are bundled and ready to load.
  3. Connect to your device — enter the device IP or COM port and start polling registers immediately.
  4. Visualise and log — build dashboards, trend data, and export readings without manual register entry.

Why Use Pre-Built Maps

  • Saves time — no need to manually look up or enter register addresses
  • Reduces errors — pre-validated maps eliminate mis-typed addresses and wrong data types
  • Speeds commissioning — connect and poll within minutes instead of hours
  • Reusable across projects — use the same map across multiple sites and installations

Data Categories Available

  • Energy
  • Power
  • Voltage
  • Frequency
  • Current
  • Status