ABB Trio 50 / Trio 60 Modbus Register Map¶
The ABB Trio 50 / Trio 60 is a solar inverter used for PV production monitoring, inverter diagnostics, and energy analytics. This page provides a sample Modbus register map with addresses, data types, and signal categories to help engineers commission, troubleshoot, and monitor the device. For ABB Trio 50 / Trio 60 deployments, teams often use this map to surface power, status, and current data in switchboards, facility power distribution, and commercial energy monitoring.
This page shows a preview subset of the full device map available in Modbus Monitor XPF.
Engineers searching for ABB Trio 50 / Trio 60 Modbus map, ABB Trio 50 / Trio 60 register map, or ABB Trio 50 / Trio 60 Modbus registers can use this page as a compatibility snapshot before importing the full map into Modbus Monitor XPF.
Overview¶
- Device: ABB Trio 50 / Trio 60
- Type: Solar Inverter
- Protocol: Modbus RTU / Modbus TCP
- Use case: PV production monitoring, inverter diagnostics, and energy analytics
- Works with: Modbus Monitor XPF (import directly)
Download Modbus Map¶
The full ABB Trio 50 / Trio 60 Modbus register map is available inside Modbus Monitor XPF as a pre-built device map. Download the free feature-locked version to access and export the complete map.
Register Table (Sample)¶
Sample registers from the ABB Trio 50 / Trio 60 Modbus map. Import the full map in Modbus Monitor XPF to access all registers.
| Signal | Address | Type | Units | Category |
|---|---|---|---|---|
| Inverter Grid Voltage V | 400304 | FLOAT32 | V | Voltage |
| Inverter Grid Current A | 400308 | FLOAT32 | - | Current |
| Dynamic Mode Power Factor Set Point Reactive Power expressed as fixed Power Factor | 400201 | FLOAT32 | PF | Power |
| Daily Energy Wh | 401071 | UINT32 | kWh | Energy |
| Mean Grid Frequency Hz | 401107 | FLOAT32 | Hz | Frequency |
| Global State | 401051 | UINT16 | - | Status |
| Internal Temperature C | 401121 | FLOAT32 | degC | Temperature |
| Remote On Off | 400181 | UINT16 | - | General |
| Accuracy Set unit for Modbus Data Addresses 0507 0508 0511 and 0512 or | 400502 | UINT16 | - | Communication |
| Set communication protocol for serial line RS485 1 | 401007 | UINT16 | - | Identification |
| Permanent Mode Power Factor Set Point Reactive Power expressed as fixed Power Factor | 400203 | FLOAT32 | PF | Power |
| Dynamic Mode Active Power Set Point Active Power Curtailment expressed as percentage of Nominal Power in steps | 400211 | UINT16 | kW | Power |
How to Use This Map¶
- Download Modbus Monitor XPF — Get the free version.
- Select the ABB Trio 50 / Trio 60 device map — pre-built maps are bundled and ready to load.
- Connect to your device — enter the device IP or COM port and start polling registers immediately.
- Visualise and log — build dashboards, trend data, and export readings without manual register entry.
Why Use Pre-Built Maps¶
- Saves time — no need to manually look up or enter register addresses
- Reduces errors — pre-validated maps eliminate mis-typed addresses and wrong data types
- Speeds commissioning — connect and poll within minutes instead of hours
- Reusable across projects — use the same map across multiple sites and installations
Data Categories Available¶
- Power
- Status
- Current
- Energy
- Voltage
- Temperature
Related Tools¶
- Modbus Monitor XPF — Windows Modbus Tool
- Modbus HMI Builder
- Compare Modbus Monitor XPF with Other Tools