Skip to content

ABB M4M Modbus Register Map

The ABB M4M is a power meter used for power monitoring, energy metering, and facility automation. This page provides a sample Modbus register map with addresses, data types, and signal categories to help engineers commission, troubleshoot, and monitor the device. Often deployed in switchboards and compact power monitoring panels.

This page shows a preview subset of the full device map available in Modbus Monitor XPF.

Engineers searching for ABB M4M Modbus map, ABB M4M register map, or ABB M4M Modbus registers can use this page as a compatibility snapshot before importing the full map into Modbus Monitor XPF.

Overview

  • Device: ABB M4M
  • Type: Power Meter
  • Protocol: Modbus RTU / Modbus TCP
  • Use case: power monitoring, energy metering, and facility automation
  • Works with: Modbus Monitor XPF (import directly)

Download Modbus Map

The full ABB M4M Modbus register map is available inside Modbus Monitor XPF as a pre-built device map. Download the free feature-locked version to access and export the complete map.

Register Table (Sample)

Sample registers from the ABB M4M Modbus map. Import the full map in Modbus Monitor XPF to access all registers.

Signal Address Type Units Category
Energy Trend Data block 1 0 433552 UINT16 kWh Energy
Max Min Demand Data block 1 0 436738 UINT16 kW Demand
Alarm number 435936 UINT16 - Status
Entry number 432769 UINT16 - General
I O port 1 435852 UINT16 - Communication
Energy Trend Data block 1 1 433553 UINT16 kWh Energy
Energy Trend Data block 1 2 433554 UINT16 kWh Energy
Energy Trend Data block 1 3 433555 UINT16 kWh Energy
Energy Trend Data block 1 4 433556 UINT16 kWh Energy
Energy Trend Data block 1 5 433557 UINT16 kWh Energy
Energy Trend Data block 1 6 433558 UINT16 kWh Energy
Energy Trend Data block 1 7 433559 UINT16 kWh Energy

How to Use This Map

  1. Download Modbus Monitor XPFGet the free version.
  2. Select the ABB M4M device map — pre-built maps are bundled and ready to load.
  3. Connect to your device — enter the device IP or COM port and start polling registers immediately.
  4. Visualise and log — build dashboards, trend data, and export readings without manual register entry.

Why Use Pre-Built Maps

  • Saves time — no need to manually look up or enter register addresses
  • Reduces errors — pre-validated maps eliminate mis-typed addresses and wrong data types
  • Speeds commissioning — connect and poll within minutes instead of hours
  • Reusable across projects — use the same map across multiple sites and installations

Data Categories Available

  • Demand
  • Energy
  • Status