Skip to content

SolarEdge SE5K / SE7K / SE10K / SE12.5K Modbus Register Map

The SolarEdge SE5K / SE7K / SE10K / SE12.5K is a solar inverter used for PV production monitoring, inverter diagnostics, and energy analytics. This page provides a sample Modbus register map with addresses, data types, and signal categories to help engineers commission, troubleshoot, and monitor the device. For SolarEdge SE5K / SE7K / SE10K / SE12.5K deployments, teams often use this map to surface voltage, current, and power data in solar inverter monitoring and renewable energy systems.

This page shows a preview subset of the full device map available in Modbus Monitor XPF.

Engineers searching for SolarEdge SE5K / SE7K / SE10K / SE12.5K Modbus map, SolarEdge SE5K / SE7K / SE10K / SE12.5K register map, or SolarEdge SE5K / SE7K / SE10K / SE12.5K Modbus registers can use this page as a compatibility snapshot before importing the full map into Modbus Monitor XPF.

Overview

  • Device: SolarEdge SE5K / SE7K / SE10K / SE12.5K
  • Type: Solar Inverter
  • Protocol: Modbus RTU / Modbus TCP
  • Use case: PV production monitoring, inverter diagnostics, and energy analytics
  • Works with: Modbus Monitor XPF (import directly)

Download Modbus Map

The full SolarEdge SE5K / SE7K / SE10K / SE12.5K Modbus register map is available inside Modbus Monitor XPF as a pre-built device map. Download the free feature-locked version to access and export the complete map.

Register Table (Sample)

Sample registers from the SolarEdge SE5K / SE7K / SE10K / SE12.5K Modbus map. Import the full map in Modbus Monitor XPF to access all registers.

Signal Address Type Units Category
I AC VoltageAB 440077 UINT16 V Voltage
I AC Current 440072 UINT16 - Current
I AC Power 440084 INT16 kW Power
I AC Energy WH 440094 UINT32 kWh Energy
I AC Frequency 440086 UINT16 Hz Frequency
I AC PF1 440092 INT16 - Power Factor
I Status 440108 UINT16 - Status
I Temp Sink 440104 INT16 - Temperature
C SunSpec ID 440001 UINT32 - General
C Model:16 440021 STRING - Identification
M Exported 440227 UINT32 - Communication
I AC CurrentA 440073 UINT16 - Current

How to Use This Map

  1. Download Modbus Monitor XPFGet the free version.
  2. Select the SolarEdge SE5K / SE7K / SE10K / SE12.5K device map — pre-built maps are bundled and ready to load.
  3. Connect to your device — enter the device IP or COM port and start polling registers immediately.
  4. Visualise and log — build dashboards, trend data, and export readings without manual register entry.

Why Use Pre-Built Maps

  • Saves time — no need to manually look up or enter register addresses
  • Reduces errors — pre-validated maps eliminate mis-typed addresses and wrong data types
  • Speeds commissioning — connect and poll within minutes instead of hours
  • Reusable across projects — use the same map across multiple sites and installations

Data Categories Available

  • Voltage
  • Current
  • Power
  • Power Factor
  • Energy
  • Status