SEL SEL-351A Modbus Register Map¶
The SEL SEL-351A is a relay used for commissioning, troubleshooting, and operational monitoring. This page provides a sample Modbus register map with addresses, data types, and signal categories to help engineers commission, troubleshoot, and monitor the device. For SEL SEL-351A deployments, teams often use this map to surface energy and power factor data in utility metering, substations, and power quality analysis.
This page shows a preview subset of the full device map available in Modbus Monitor XPF.
Engineers searching for SEL SEL-351A Modbus map, SEL SEL-351A register map, or SEL SEL-351A Modbus registers can use this page as a compatibility snapshot before importing the full map into Modbus Monitor XPF.
Overview¶
- Device: SEL SEL-351A
- Type: Relay
- Protocol: Modbus RTU / Modbus TCP
- Use case: commissioning, troubleshooting, and operational monitoring
- Works with: Modbus Monitor XPF (import directly)
Download Modbus Map¶
The full SEL SEL-351A Modbus register map is available inside Modbus Monitor XPF as a pre-built device map. Download the free feature-locked version to access and export the complete map.
Register Table (Sample)¶
Sample registers from the SEL SEL-351A Modbus map. Import the full map in Modbus Monitor XPF to access all registers.
| Signal | Address | Type | Units | Category |
|---|---|---|---|---|
| ForwardEnergy | 300031 | FLOAT32 | kWh | Energy |
| PFapparentTotal | 300027 | FLOAT32 | - | Power Factor |
| Ptrip.6 | 100001 | BIT | - | General |
| ReverseEnergy | 300033 | FLOAT32 | kWh | Energy |
| 50A1pickup.7 | 100003 | BIT | - | General |
| 50A2pickup.4 | 100003 | BIT | - | General |
| 50A3pickup.1 | 100003 | BIT | - | General |
| 50B1pickup.6 | 100003 | BIT | - | General |
| 50B2pickup.3 | 100003 | BIT | - | General |
| 50B3pickup.0 | 100003 | BIT | - | General |
| 50C1pickup.5 | 100003 | BIT | - | General |
| 50C2pickup.2 | 100003 | BIT | - | General |
How to Use This Map¶
- Download Modbus Monitor XPF — Get the free version.
- Select the SEL SEL-351A device map — pre-built maps are bundled and ready to load.
- Connect to your device — enter the device IP or COM port and start polling registers immediately.
- Visualise and log — build dashboards, trend data, and export readings without manual register entry.
Why Use Pre-Built Maps¶
- Saves time — no need to manually look up or enter register addresses
- Reduces errors — pre-validated maps eliminate mis-typed addresses and wrong data types
- Speeds commissioning — connect and poll within minutes instead of hours
- Reusable across projects — use the same map across multiple sites and installations
Data Categories Available¶
- Energy
- Power Factor