Janitza UMG511 Modbus Register Map

The Janitza UMG511 is a power meter used for power monitoring, energy metering, and facility automation. This page provides a sample Modbus register map with addresses, data types, and signal categories to help engineers commission, troubleshoot, and monitor the device. For Janitza UMG511 deployments, teams often use this map to surface harmonics, power, and power factor data in facility metering, commissioning, and operational analytics.

This page shows a preview subset of the full device map available in Modbus Monitor XPF.

Engineers searching for Janitza UMG511 Modbus map, Janitza UMG511 register map, or Janitza UMG511 Modbus registers can use this page as a compatibility snapshot before importing the full map into Modbus Monitor XPF. Also aligns to search intent around Janitza UMG511 Modbus register, Janitza UMG511 Modbus address list.

Overview

  • Device: Janitza UMG511
  • Type: Power Meter
  • Protocol: Modbus RTU / Modbus TCP
  • Use case: power monitoring, energy metering, and facility automation
  • Works with: Modbus Monitor XPF (import directly)

Download Modbus Map

The full Janitza UMG511 Modbus register map is available inside Modbus Monitor XPF as a pre-built device map. Download the free feature-locked version to access and export the complete map.

Register Table (Sample)

Sample registers from the Janitza UMG511 Modbus map. Import the full map in Modbus Monitor XPF to access all registers.

Signal Address Type Units Category
Voltage L1 N V 419000 FLOAT32 V Voltage
Apparent current L1 N A 419012 FLOAT32 A Current
Real power L1 N W 419020 FLOAT32 kW Power
Real energy L1 Wh 419054 FLOAT32 kWh Energy
Measured frequency Hz 419050 FLOAT32 Hz Frequency
PFLN_0 403893 FLOAT32 - Power Factor
PTP_STATE 314562 INT32 - Status
TEMPERATUR 404209 FLOAT32 - Temperature
Harmonic thd u L1 N 419110 FLOAT32 - Harmonics
Vector sum ini1i2i3 A 419018 FLOAT32 - General
BAUD485 306951 INT32 - Communication
PTP_VERSION 314548 INT16 - Identification

How to Use This Map

  1. Download Modbus Monitor XPFGet the free version.
  2. Select the Janitza UMG511 device map — pre-built maps are bundled and ready to load.
  3. Connect to your device — enter the device IP or COM port and start polling registers immediately.
  4. Visualise and log — build dashboards, trend data, and export readings without manual register entry.

Why Use Pre-Built Maps

  • Saves time — no need to manually look up or enter register addresses
  • Reduces errors — pre-validated maps eliminate mis-typed addresses and wrong data types
  • Speeds commissioning — connect and poll within minutes instead of hours
  • Reusable across projects — use the same map across multiple sites and installations

Data Categories Available

  • Harmonics
  • Power
  • Power Factor
  • Energy
  • Temperature
  • Voltage