Huawei Sun2000 -env Modbus Register Map¶
The Huawei Sun2000 -env is a solar inverter used for PV production monitoring, inverter diagnostics, and energy analytics. This page provides a sample Modbus register map with addresses, data types, and signal categories to help engineers commission, troubleshoot, and monitor the device. For Huawei Sun2000 -env deployments, teams often use this map to surface power, temperature, and current data in solar inverter monitoring and renewable energy systems.
This page shows a preview subset of the full device map available in Modbus Monitor XPF.
Engineers searching for Huawei Sun2000 -env Modbus map, Huawei Sun2000 -env register map, or Huawei Sun2000 -env Modbus registers can use this page as a compatibility snapshot before importing the full map into Modbus Monitor XPF. Also aligns to search intent around Huawei Sun2000 -env Modbus TCP register, Huawei Sun2000 -env Modbus register map.
Overview¶
- Device: Huawei Sun2000 -env
- Type: Solar Inverter
- Protocol: Modbus RTU / Modbus TCP
- Use case: PV production monitoring, inverter diagnostics, and energy analytics
- Works with: Modbus Monitor XPF (import directly)
Download Modbus Map¶
The full Huawei Sun2000 -env Modbus register map is available inside Modbus Monitor XPF as a pre-built device map. Download the free feature-locked version to access and export the complete map.
Register Table (Sample)¶
Sample registers from the Huawei Sun2000 -env Modbus map. Import the full map in Modbus Monitor XPF to access all registers.
| Signal | Address | Type | Units | Category |
|---|---|---|---|---|
| Inverter 1 total DC input current | 451004 | INT16 | - | Current |
| Inverter 1 active power kW | 451000 | INT32 | kW | Power |
| Inverter 1 inverter status | 451009 | UINT16 | - | Status |
| Inverter 1 cabinet temperature | 451011 | INT16 | degC | Temperature |
| Inverter 1 insulation resistance M | 451007 | UINT16 | - | General |
| Inverter 1 reactive power | 451002 | INT32 | kW | Power |
| Inverter 1 total input power kW | 451005 | UINT32 | kW | Power |
| Inverter 1 power factor | 451008 | INT16 | PF | Power |
| Inverter 2 active power kW | 451025 | INT32 | kW | Power |
| Inverter 2 reactive power | 451027 | INT32 | kW | Power |
| Inverter 2 total DC input current | 451029 | INT16 | - | Current |
| Inverter 2 total input power kW | 451030 | UINT32 | kW | Power |
How to Use This Map¶
- Download Modbus Monitor XPF — Get the free version.
- Select the Huawei Sun2000 -env device map — pre-built maps are bundled and ready to load.
- Connect to your device — enter the device IP or COM port and start polling registers immediately.
- Visualise and log — build dashboards, trend data, and export readings without manual register entry.
Why Use Pre-Built Maps¶
- Saves time — no need to manually look up or enter register addresses
- Reduces errors — pre-validated maps eliminate mis-typed addresses and wrong data types
- Speeds commissioning — connect and poll within minutes instead of hours
- Reusable across projects — use the same map across multiple sites and installations
Data Categories Available¶
- Power
- Temperature
- Current
- Status