Skip to content

Huawei Solar Inverter Modbus Register Map

The Huawei Solar Inverter is a power meter used for power monitoring, energy metering, and facility automation. This page provides a sample Modbus register map with addresses, data types, and signal categories to help engineers commission, troubleshoot, and monitor the device. For Huawei Solar Inverter deployments, teams often use this map to surface power, temperature, and current data in facility metering, commissioning, and operational analytics.

This page shows a public register preview. Check the catalog in your installed XPF version for complete-map availability and licensing.

Confirm the exact model and firmware, address base, register function, word order, scaling and units against the manufacturer manual before polling. This preview does not establish hardware validation.

Overview

  • Device: Huawei Solar Inverter
  • Type: Power Meter
  • Protocol: Confirm the supported transport for the exact device and firmware in the manufacturer manual.
  • Use case: power monitoring, energy metering, and facility automation
  • Works with: Modbus Monitor XPF (import directly)

Download Modbus Map

The sample below is a public preview. Check the catalog in your installed XPF version for current availability, access and licensing.

Public JSON preview · Preview data terms

Register Table (Sample)

Sample registers from the Huawei Solar Inverter Modbus map. Confirm the sample against the exact device and firmware before use.

Signal Address Type Units Category
Inverter 1 total DC input current 451004 INT16 - Current
Inverter 1 active power kW 451000 INT32 kW Power
Inverter 1 inverter status 451009 UINT16 - Status
Inverter 1 cabinet temperature 451011 INT16 degC Temperature
Inverter 1 insulation resistance M 451007 UINT16 - General
Inverter 1 reactive power 451002 INT32 kW Power
Inverter 1 total input power kW 451005 UINT32 kW Power
Inverter 1 power factor 451008 INT16 PF Power
Inverter 2 active power kW 451025 INT32 kW Power
Inverter 2 reactive power 451027 INT32 kW Power
Inverter 2 total DC input current 451029 INT16 - Current
Inverter 2 total input power kW 451030 UINT32 kW Power

How to Use This Map

  1. Download Modbus Monitor XPF — Get the free version.
  2. Select the Huawei Solar Inverter device map — check availability and access in the installed application catalog.
  3. Connect to your device — confirm transport, addressing and data types before starting a read operation.
  4. Visualise and log — build dashboards, trend data, and export readings without manual register entry.

Why Use Pre-Built Maps

  • Saves time — no need to manually look up or enter register addresses
  • Reduces errors — reusable maps reduce repeated manual entry; validate addresses and data types for your device
  • Speeds commissioning — connect and poll within minutes instead of hours
  • Reusable across projects — use the same map across multiple sites and installations

Data Categories Available

  • Power
  • Temperature
  • Current
  • Status