GE EPM 7000 / EPM 7100 Modbus Register Map¶
The GE EPM 7000 / EPM 7100 is a power meter used for power monitoring, energy metering, and facility automation. This page provides a sample Modbus register map with addresses, data types, and signal categories to help engineers commission, troubleshoot, and monitor the device. For GE EPM 7000 / EPM 7100 deployments, teams often use this map to surface demand, current, and power factor data in facility metering, commissioning, and operational analytics.
This page shows a preview subset of the full device map available in Modbus Monitor XPF.
Engineers searching for GE EPM 7000 / EPM 7100 Modbus map, GE EPM 7000 / EPM 7100 register map, or GE EPM 7000 / EPM 7100 Modbus registers can use this page as a compatibility snapshot before importing the full map into Modbus Monitor XPF.
Overview¶
- Device: GE EPM 7000 / EPM 7100
- Type: Power Meter
- Protocol: Modbus RTU / Modbus TCP
- Use case: power monitoring, energy metering, and facility automation
- Works with: Modbus Monitor XPF (import directly)
Download Modbus Map¶
The full GE EPM 7000 / EPM 7100 Modbus register map is available inside Modbus Monitor XPF as a pre-built device map. Download the free feature-locked version to access and export the complete map.
Register Table (Sample)¶
Sample registers from the GE EPM 7000 / EPM 7100 Modbus map. Import the full map in Modbus Monitor XPF to access all registers.
| Signal | Address | Type | Units | Category |
|---|---|---|---|---|
| Phase A Voltage harmonic magnitudes | 406005 | UINT16 | V | Voltage |
| Amps A | 400284 | UINT16 | A | Current |
| Power Factor 3 Ph total | 400291 | INT16 | PF | Power |
| Power Energy Format | 430005 | UINT16 | kWh | Energy |
| Frequency | 400292 | UINT16 | Hz | Frequency |
| Positive PF 3 Ph Average | 402015 | FLOAT32 | - | Power Factor |
| Volts A N previous Demand interval Short Term Minimum | 407975 | FLOAT32 | kW | Demand |
| Meter Status | 404500 | UINT16 | - | Status |
| Unit Lifetime Data Max Temperature | 404536 | FLOAT32 | degC | Temperature |
| Volts A N THD | 405999 | UINT16 | - | Harmonics |
| Meter Name:8 | 400000 | STRING | - | Identification |
| Meter Type | 400016 | UINT16 | - | General |
How to Use This Map¶
- Download Modbus Monitor XPF — Get the free version.
- Select the GE EPM 7000 / EPM 7100 device map — pre-built maps are bundled and ready to load.
- Connect to your device — enter the device IP or COM port and start polling registers immediately.
- Visualise and log — build dashboards, trend data, and export readings without manual register entry.
Why Use Pre-Built Maps¶
- Saves time — no need to manually look up or enter register addresses
- Reduces errors — pre-validated maps eliminate mis-typed addresses and wrong data types
- Speeds commissioning — connect and poll within minutes instead of hours
- Reusable across projects — use the same map across multiple sites and installations
Data Categories Available¶
- Demand
- Current
- Power Factor
- Harmonics
- Status
- Voltage
Related Tools¶
- Modbus Monitor XPF — Windows Modbus Tool
- Modbus HMI Builder
- Compare Modbus Monitor XPF with Other Tools