Skip to content

Fronius Inverter Common Modbus Register Map

The Fronius Inverter Common is a power meter used for power monitoring, energy metering, and facility automation. This page provides a sample Modbus register map with addresses, data types, and signal categories to help engineers commission, troubleshoot, and monitor the device. For Fronius Inverter Common deployments, teams often use this map to surface power, voltage, and current data in facility metering, commissioning, and operational analytics.

This page shows a preview subset of the full device map available in Modbus Monitor XPF.

Engineers searching for Fronius Inverter Common Modbus map, Fronius Inverter Common register map, or Fronius Inverter Common Modbus registers can use this page as a compatibility snapshot before importing the full map into Modbus Monitor XPF.

Overview

  • Device: Fronius Inverter Common
  • Type: Power Meter
  • Protocol: Modbus RTU / Modbus TCP
  • Use case: power monitoring, energy metering, and facility automation
  • Works with: Modbus Monitor XPF (import directly)

Download Modbus Map

The full Fronius Inverter Common Modbus register map is available inside Modbus Monitor XPF as a pre-built device map. Download the free feature-locked version to access and export the complete map.

Register Table (Sample)

Sample registers from the Fronius Inverter Common Modbus map. Import the full map in Modbus Monitor XPF to access all registers.

Signal Address Type Units Category
AC voltage phase AB V 440076 UINT16 V Voltage
Total AC current A 440071 UINT16 - Current
AC in feed power W 440083 INT16 kW Power
Total fed-in energy Wh 440093 UINT32 kWh Energy
AC frequency Hz 440085 UINT16 Hz Frequency
Housing temperature C 440102 INT16 degC Temperature
Operating mode Bitmask 440107 UINT16 - General
AC current phase A A 440072 UINT16 A Current
AC current phase B A 440073 UINT16 A Current
AC current phase C A 440074 UINT16 A Current
Scale factor AC current SF 440075 INT16 - Current
AC voltage phase BC V 440077 UINT16 V Voltage

How to Use This Map

  1. Download Modbus Monitor XPFGet the free version.
  2. Select the Fronius Inverter Common device map — pre-built maps are bundled and ready to load.
  3. Connect to your device — enter the device IP or COM port and start polling registers immediately.
  4. Visualise and log — build dashboards, trend data, and export readings without manual register entry.

Why Use Pre-Built Maps

  • Saves time — no need to manually look up or enter register addresses
  • Reduces errors — pre-validated maps eliminate mis-typed addresses and wrong data types
  • Speeds commissioning — connect and poll within minutes instead of hours
  • Reusable across projects — use the same map across multiple sites and installations

Data Categories Available

  • Power
  • Voltage
  • Current
  • Temperature
  • Frequency
  • Energy